Structural Calculations for Chimney Breast Removal
Structura provides structural assessments and calculations for chimney breast removal across Essex and London. A chimney breast supports the masonry above it, so before one is taken out, an engineer needs to work out what will hold up the part that stays.
Prefer to talk? Call us on 01277 549 086.
This service covers the structural assessment and calculations. The removal itself is carried out by your builder. If you’re opening up a wall as well, see steel beam and RSJ calculations.
Removing a ground floor chimney breast
Taking out the chimney breast downstairs leaves the masonry upstairs, in the loft and above the roof without its original support. That remaining weight can be considerable, and it usually needs a steel beam at first floor level.
The calculations consider both the beam and the walls it will rest on.
Removing a first floor chimney breast
When a bedroom chimney breast is removed and the stack stays, support is normally needed in the loft. The right method depends on the size and condition of the stack, the wall behind it and any flues that are still in use.
Brickwork that’s left in place shouldn’t be relied on to hold itself up, even if it looks stable.
Removing the whole chimney
If the stack and every section of chimney breast are removed, there’s no masonry left above to support, but the wall, floors and roof still have to be made good. A chimney breast can also stiffen the wall it’s attached to, so that wall may need checking.
Changes outside can need planning permission, particularly in a conservation area. A listed building needs listed building consent for work inside or out that affects its character.
Steel beams or gallows brackets?
Steel beams are the usual way to support a chimney that remains. Gallows brackets are sometimes used for smaller stacks, but they depend on the strength of the wall and aren’t accepted in every case.
Whether your neighbour has removed their side of a shared chimney also matters. Check with Building Control before settling on brackets.
Chimney breast removal calculations in Essex and London
We provide chimney breast removal calculations across Essex and London, as part of our Structural Engineering division.
Other structural engineering services
How it works
Send photos
Confirm the assessment
Receive the calculations
What clients say about Structura
Frequently asked questions
Common questions about chimney breast removal.
In most cases, yes. If any part of the chimney stays above the section being removed, Building Control will normally expect calculations for its support.
Yes. It’s a structural alteration, so tell Building Control before work starts. They will also consider fire safety, sound insulation and ventilation.
It depends on how much is being removed, what stays and the type of support needed. Send photos and details for a quote.
If the chimney breast is attached to a shared wall, you’ll usually need to serve notice on your neighbour under the Party Wall etc. Act 1996. Our party wall surveyors can help.
Don’t start work. A flue serving a gas appliance must be checked by a Gas Safe registered engineer, and any other live flues, including a neighbour’s, must be identified before anything is removed.
No. We provide the structural assessment and calculations, and your builder carries out the work.
Get a quote for chimney breast removal calculations
Tell us which parts you want to remove and attach photos of each floor, the loft and the outside.






